Wood Burning Fireplace Piping
UL 127 Listed 1700 Degree Standard Piping




8" Standard Pipe & Accessories



ModelDescription
CP-8DMChimney Pack
(Firestop: , Rooflashing: V6F-8DM, Storm Collar: , & Termination Cap: )
12-8DM12" Section of Double Wall Pipe
18-8DM18" Section of Double Wall Pipe
24-8DM24" Section of Double Wall Pipe
36-8DM36" Section of Double Wall Pipe
48-8DM48" Section of Double Wall Pipe
30E-8DM30 Degree Offset & Return Elbow Set
12S-8DM12" Chimney Support Pipe (For Systems Above 30')
FS-8DM2" Clearance Firestop Spacer Required at Ceiling
(Standard 42" Models & 8" Multi View)
Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. They also provide complete separation from one floor space to
another or attic space as required by most codes.

FS-1-8DM30 Degree Firestop Spacer
3600FS-8DM-11" Clearance Firestop Spacer
(Standard 36" Models)
V6F-8DM0 to 6/12 Pitch Roof Flashing
(Use With RTL Terminations)
V12F-8DM6/12 to 12/12 Pitch Roof Flashing
(Use With RTL Terminations)
38FSTFirestop Thimble
(Use when penetrating a joist)
FST30Firestop Thimble
(Use when offsetting through a joist)
38RSRoof Support
(Use with flashing)
ADS-8DMAnti-Draft Shield
(Use With RTL or RTTL)





8" Double Wall Termination



ModelDescription
RT-8DMRound Top Termination
(Use with CWB Series Only)
RTT-8DMRound Top with Slip
(Use with CWB Series Only)
RLT-8DM Round Top Termination
(Roof or Chase System - Use with all 8" systems)
4" Gain
RLTT-8DM Round Top Telescoping (Chase System Only)
1-17" Gain
ET-8DMSquare Top
ETL-8DMSquare Top  (Chase System Only)
1-12" Gain
ETO-8DMSquare Top with Mesh
ETLO-8DMSquare Top with Mesh & Slip Section





Black Painted 8" Double Wall Termination



ModelDescription
RLT-8DM-K Painted Round Top Termination
(Roof or Chase System - Use with all 8" systems)
4" Gain
ETL-8DM-KPainted Square Top  (Chase System Only)
1-12" Gain




Storm Collar



ModelDescription
SC1-1Storm Collar
(Use With RTL Terminations)
Use SC1 for all round terminations





Important Heater Information



  • Installation must be done by qualified service persons.
  • Read Owner's Manual before using.
  • Not for use in recreational vehicles.
  • We reserve the right to amend product specifications without notice.
  • Use with adequate air (ventilation) only. Humidifies while it heats.
  • Provides water vapor in the area heated. Refer to owner's manual for specifics.
  • Heating areas based on rooms with 8' ceilings.
  • Operating heater at elevations above 4,500 ft. could cause nuisance outages.
  • ANSI Z21 11.2 Standard and National Fuel Gas Code revised in 1994 to permit wall mounted installations of vent-free gas heaters of 10,000 Btu or less in bedrooms and 6,000 Btu or less in Bathrooms. As always check local codes




Technical Tips